Isiqulatho
Inkqubo yezixhobo ze-XBX ze-bronchoscope yenzelwe ukuhambisa umfanekiso ocacileyo, ukuhamba kakuhle, kunye nokusebenza okuthembekileyo kwi-pulmonary diagnostics kunye nokungenelela. Injineli phantsi kwe-ISO 13485, CE, kunye nemigangatho ye-FDA, umgca we-bronchoscope we-XBX udibanisa ukuchaneka kwe-optical, ukuphathwa kwe-ergonomic, kunye nokuqina kokuqina. Izibhedlele kwihlabathi jikelele zithembele kuyo kwiziphumo zebronchoscopy ezingaguqukiyo kunye nokunciphisa iindleko zizonke zokulungisa.
Uyilo lwezixhobo ze-bronchoscope ze-XBX lugxininisa ukucaca, ukuguquguquka, kunye nokulawula usulelo. Icandelo ngalinye-ukusuka kwi-distal lens ukuya kwicandelo lokulawula-lenziwe ukuba linike ukuhamba ngokuchanekileyo kwiindlela zomoya ngelixa ligcina induduzo yesigulane kunye nokhuseleko lwenkqubo. Xa kuthelekiswa neemveliso eziqhelekileyo, i-XBX isebenzisa izixhobo ze-premium-grade kunye nokuqinisekiswa kwenkqubo yedijithali ukufezekisa ukuthembeka kwexesha elide kwiindawo ezibhedlele ezifunayo.
Izinzwa eziphezulu ze-CMOS zihambisa imifanekiso ebukhali yeendonga zomoya kunye nezakhiwo ze-bronchial, ukuphucula ukuchaneka kokuchongwa kwesilonda.
Imicu yokukhanyisa ilungiselelwe ukukhanya okufanayo kunye nomthunzi omncinci, okuvumela oogqirha ukuba bagcine ukubonakala okucacileyo nakwi-peripheral bronchi.
Iilensi zokugquma zixhathisa inkungu kunye nokuqokelelana kwamathontsi amanzi, ukunciphisa ukuphazamiseka kwenkqubo.
Isixhobo se-bronchoscope se-XBX sibonisa ulwakhiwo olukhaphukhaphu kunye nesibambo solawulo esine-intuitive ukwenzela intshukumo yengcebiso echanekileyo. I-angulation egudileyo, amacandelo okugoba aqiniweyo, kunye nempendulo yetorque elungeleleneyo ivumela abaqhubi ukuba bahambe ngeendlela zomoya ezintsonkothileyo ngokukhululeka. Uyilo lunciphisa ukudinwa kwesandla, okubalulekileyo ngexesha leenkqubo ezinde ezifana ne-bronchoscopy yonyango okanye i-endobronchial biopsy.
Zonke izixhobo zokunxibelelana nesigulana ziyahlangabezana nemigangatho ye-ISO 10993 biocompatibility kwaye ziqinisekisiwe kwimijikelo ephindaphindiweyo yokuvala inzala.
Imijelo yakhiwe ngeentambo zangaphakathi ezingenamthungo zokunciphisa ukunamathela kwebhaktheriya kunye nokwenza lula ukucoca.
Uvavanyo lokuvuza kunye nokuhlolwa kwemfezeko yoxinzelelo lwenziwa kwiyunithi nganye ngaphambi kokuthunyelwa ukuthintela imingcipheko yongcoliseko olunqamlezayo.
Ngaphakathi kumzi-mveliso we-XBX, ukuveliswa kwe-bronchoscope kudibanisa ubunjineli obuchanekileyo, ukuhlola okuzenzekelayo, kunye nokulandelwa kwedijithali. Oku kuqinisekisa ukuba isixhobo ngasinye se-bronchoscopy esishiya umgca wemveliso sidibana nomgangatho ophezulu ofanayo wokusebenza kwamehlo kunye nokunyaniseka komatshini. Abavelisi abaqhelekileyo bavame ukuthembela kwindibano yezandla, eyazisa ukuguquguquka-i-XBX isusa oko ngokulawulwa kwedatha.
Amacandelo abalulekileyo afana neetyhubhu zokufaka kunye ne-distal lens ziveliswa phantsi kweenkqubo ze-machining ezilawulwa yi-SPC.
Uhlolo oluzenzekelayo lwamehlo luqinisekisa ulungelelwaniso kunye nokungaguquguquki kwesisombululo kuzo zonke iibhetshi.
I-torque kunye nokugoba ukuqina kwemephu kuqinisekisa iimpawu zokuphatha ezifanayo phakathi kweeyunithi.
Izakhiwo ze-coil zensimbi engenasici kunye ne-multi-layer polymer sheathing zikhusela amacandelo angaphakathi ekunxibeni kunye nokuguqulwa. Amacandelo okugoba asebenzisa i-alloys ekwazi ukumelana nokudinwa ukugcina ukusebenza emva kwamawaka emijikelezo yokucacisa. Ngenxa yoko, izixhobo ze-XBX ze-bronchoscope zibonisa ubomi obandisiweyo xa kuthelekiswa neemodeli eziqhelekileyo, ukunciphisa ukuphindaphinda kokutshintshwa kunye neendleko ezipheleleyo kwizibhedlele.
I-bronchoscope nganye i-serialized kwaye idibaniswe nokugqiba iirekhodi zokuhlola, ukuvumela izibhedlele ukuba zifikelele kwi-calibration kunye nokugcinwa kwedatha ngokulula.
Ukuthotyelwa kwe-UDI (Unique Device Identification) kwenza ukuba kulandelelwe ngeenkqubo ze-asethi zezibhedlele zehlabathi.
Amaxwebhu abanzi axhasa ukuthengwa kwezinto elubala nophicotho-zincwadi olulawulayo.
Oogqirha abasebenzisa izixhobo ze-XBX ze-bronchoscopy bazuza ngokuchaneka kwe-imaging ephezulu kunye nokudibanisa ukuhamba komsebenzi. Ukudityaniswa kokucaca kwe-optical, i-angulation ethembekileyo, kunye nolawulo olucacileyo luphucula ukusebenza kakuhle kwenkqubo kuxilongo kunye ne-bronchoscopy yonyango ngokufanayo.
Imveliso ehambelana ne-4K iphucula ukubonwa kwezilonda ze-mucosal kunye neepatheni ze-vascular.
Ubunzulu obuphuculweyo bunceda ekujoliseni indawo ye-biopsy kunye nesikhokelo sesixhobo.
Ukuhambelana kombala womfanekiso kuxhasa ukwahlula okuchanekileyo kwezicubu phantsi kokukhanya okuguquguqukayo.
Umatshini we-bronchoscope we-XBX ufaka izixhobo ezifana ne-biopsy forceps, i-cytology brushes, kunye ne-cryoprobes. Iinguqu zeshaneli ezigudileyo zinciphisa ukungqubana, zivumela ukutshintshiselana kwesixhobo esikhawulezayo ngexesha le-bronchoscopy yokungenelela. Oku kunciphisa ixesha lenkqubo kunye nokuphucula ukuchaneka ngexesha lokucocwa kwe-airway okanye iinkqubo zokususwa kwe-tumor.
Ukudityaniswa kwe-plug-and-play kunye neenkqubo ze-endoscopy ze-XBX ziqinisekisa ukusekwa ngokukhawuleza kumagumbi okusebenza kunye nee-ICU.
Iimpawu ze-auto-calibration zinciphisa ixesha lokulungiselela, ukunceda oogqirha bagxininise ekunyamekelweni kwesigulane.
Uyilo olubambeneyo lwenza lula ugcino kunye nothutho, luyenze ilungele zombini izibhedlele ezinkulu kunye neekliniki ezihambayo.
I-XBX inikezela ngezisombululo ezinokusetyenziswa kwakhona kunye nezisebenzise enye ye-bronchoscope. Iimodeli ze-bronchoscope ezilahlwayo zifanelekile kwiindawo ezinokuthi zithintele usulelo ezifana nee-ICU okanye amasebe kaxakeka. Babonelela ngomgangatho ofanayo womfanekiso ngelixa besusa imingcipheko yongcoliseko olunqamlezayo kunye neendleko zokuphinda zicutshungulwe, zibonelela ngokuguquguquka kubalawuli bezibhedlele abalawula iimfuno zenkqubo ezahlukeneyo.
Yonke i-bronchoscope ye-XBX iphantsi kovavanyo olunzulu lokusebenza ngaphambi kokuthunyelwa. Ulawulo lovavanyo luphindaphinda uxinzelelo lokwenyani lweklinikhi, luqinisekisa ukuba oomatshini, amehlo, kunye nemisebenzi ye-elektroniki ihlala izinzile kubo bonke ubomi babo benkonzo.
Isisombululo, ukugqwethwa, kunye nokuchaneka kombala ziqinisekiswa ngokuchasene neetshathi zovavanyo ezilinganisiweyo.
Ukukhanya kokukhanya kunye nokusebenza kakuhle kokuhanjiswa kwefayibha kulinganiselwa kwimveliso efanayo.
Iiprosesa zemifanekiso ziyadityaniswa ukuze kuqinisekiswe usasazo lwevidiyo oluyi-zero-latency.
Ibronchoscope nganye igotywe kumjikelo opheleleyo we-angulation amaxesha angamawaka ukuqinisekisa ukuqina.
Iityhubhu zokufakela zivavanyelwa amandla okuqina kunye nokumelana noxinzelelo.
Izibambo zolawulo zivavanyelwa ukuhambelana kwetorque kunye nokuzinza kwe-ergonomic phantsi kokusetyenziswa okwandisiweyo.
Iimvavanyo zokuvuza kwe-Helium ziqinisekisa ukuthembeka kwesiteshi emva koxinzelelo lwe-thermal kunye noxinzelelo.
Imijikelo ephindaphindiweyo yokuvala inzala ilinganisa iminyaka yokusetyenziswa kwezonyango ngaphandle kokuthotywa kwetywina okanye i-optics.
Izihluzi zeHydrophobic kunye neenkqubo zevalvu zivavanyelwa ukhuseleko lokuhamba komoya kunye nokusebenza komqobo webhaktheriya.
Ukuvuza kwangoku kunye novavanyo lokumelana nokufakelwa luqinisekisa ukhuseleko lwesigulane kunye nabaqhubi.
Uvavanyo lwe-EMC luqinisekisa ukuba inkqubo ye-bronchoscope isebenza ngokuthembekileyo ecaleni kwezinye izixhobo zotyando.
Ukuqhubekeka komgangatho kunye neenkqubo zokubeka iliso kubushushu zihlangabezana neemfuno ze-IEC 60601-1.
Izibhedlele ezamkela izixhobo ze-XBX ze-bronchoscopy zizuza kwipakethe ebanzi yobuchwepheshe, ukhuseleko, kunye nokuthembeka kwenkonzo. Inika ixesha eliphezulu eliphezulu, ukuchaneka kwe-imaging engcono, kunye neeshedyuli zolondolozo oluqikelelweyo, okwenza kube utyalo-mali oluneendleko ezifanelekileyo kwiiyunithi zokhathalelo lwe-pulmonary kunye namasebe otyando.
Iindleko eziphantsi zobomi ngenxa yobude bemveliso eyandisiweyo kunye nesantya esincitshisiweyo sokusilela.
Ukuphuculwa kwexesha lokuguqula inkqubo ngokuseta lula kunye neemfuno zokugcinwa okuncinci.
Ukuhambelana kwiinkqubo ezininzi zokucinga, ukuvumela ukusetyenziswa okwabelwanayo ngaphakathi kwamasebe e-endoscopy.
Imifanekiso ebukhali ixhasa ukuxilongwa kwangoko kwezilonda zomoya kunye nosulelo.
Ukunciphisa ukungonwabi kwesigulana ukusuka ekufakweni okugudileyo kunye nobude benkqubo emfutshane.
Ukucinga okuzinzile kunye nokulawulwa kwamanzi kunciphisa iingxaki ngexesha le-bronchoscopy.
Isixhobo se-bronchoscope se-XBX sithenjwa zizibhedlele kumazwekazi ngokusebenza kwayo okungaguqukiyo, uthungelwano lwenkonzo eyomeleleyo, kunye namaxwebhu okwenziwa elubala. Amaqela ezonyango ayayixabisa inkxaso ye-XBX yobugcisa obuphendulayo, eqinisekisa ukuqhubeka nokusebenza nakwiiyunithi ze-pulmonary ezifunwa kakhulu. Ngokuqhubekayo ngokutsha kunye nengxelo yeklinikhi, i-XBX igcina ubunkokeli kwi-teknoloji ye-bronchoscopy.
Isixhobo se-bronchoscope se-XBX sibonisa indlela ubunjineli obuchanekileyo kunye noyilo oluqhutywa ngokhuseleko lunokuguqula ukuxilongwa kwemiphunga. Ngokudibanisa i-imaging ephezulu, ukuphathwa kwe-ergonomic, kunye nokuqina kwexesha elide, i-XBX inikezela izibhedlele isisombululo esinokwethenjelwa kwiinkqubo ze-bronchoscopy ezifuna ukuchaneka nokuthembeka. Olu gxininiso lokuhambelana, ukhuseleko, kunye nexabiso leklinikhi lichaza ukuba kutheni i-XBX ihlala igama elikhethiweyo kukhathalelo lokuphefumula lwangoku.
Isixhobo se-bronchoscope se-XBX sidibanisa i-high-resolution ye-CMOS imaging, i-articulation egudileyo, kunye ne-ISO 13485-certified production. Ezi zinto ziqinisekisa ukubonakala okucacileyo, impendulo yetorque engaguqukiyo, kunye nokuthembeka okukhethekileyo xa kuthelekiswa neebronchoscopes eziqhelekileyo.
I-bronchoscope nganye ivavanywa ngokuvuza kwe-helium, ukuqinisekiswa kwe-insulation, kunye nokuqinisekiswa kwe-biocompatibility. Inkqubo yokuvelisa ithobela i-ISO 13485, CE, kunye nemigangatho ye-FDA ukuqinisekisa ukhuseleko lombane kunye nebhayoloji kwizigulana kunye nabasebenzi bezonyango.
Ewe. I-bronchoscope ye-XBX idibanisa ngokungenamthungo kwiinkqubo ezininzi ze-endoscopy zesibhedlele ezikhoyo kunye neeprosesa. Uyilo lwayo lwe-plug-and-play luvumela oogqirha ukuba badibanise ngaphandle kokuguqula ukuhamba komsebenzi okanye iziseko.
Ewe. I-XBX ibonelela nge-bronchoscopes enye yokusetyenziswa ngokufanelekileyo kwi-ICU kunye namagumbi okuxakeka, apho ulawulo losulelo kunye nokuguqulwa ngokukhawuleza kubaluleke kakhulu. Iimodeli ezilahlwayo zigcina umgangatho ofanayo wokucinga njengezo zisebenzisekayo kwakhona ngelixa zisusa ixesha lokuphinda lisetyenziswe.
Ngokulungiswa okufanelekileyo, i-XBX i-bronchoscopes ephinda isetyenziswe iyakwazi ukudlula i-1,000 ye-articulation kunye ne-sterilization cycles ngaphandle kokuthotywa kwe-optical or mechanical performance, i-experforming standard devices in lifespan and stability.
Copyright © 2025.Geekvalue Onke amalungelo agciniwe.Uxhaso lobuchwepheshe: TiaoQingCMS